MENENTUKAN TINGKAT INTENSITAS RADIASI UV YANG DITERIMA PEKERJA PENGELASAN DENGAN TITIK AREA MATA, SIKU, DAN BETIS
View/ Open
Date
2021-06Author
Muliana, Muliana
Subagiada, Kadek
Natalisanto, Adrianus Inu
Metadata
Show full item recordAbstract
The aim of this study is to measure the UV intensity received by the welders during working
time and compare the results of measured radiation intensity which is obtained with the NAB in
Regulation of the Minister of Manpower No. 05 of 2018 that is 0,0008 mW/cm2
. The reason for
using this NAB is for compare value while welding process with the value were allowed from
Regulation of the Minister of Manpower. This study has been done in some workshops using
the UV Meter and focused on the welders’ eye, elbow and calf area with 10 repetitions in each
area. The results for eye area were 0.0749 mW/cm2
, for elbow area were 0.0843 mW/cm2
and
for calf area were 0.0934 mW/cm2
and all the results obtained exceed the NAB. The high value
is caused by the environmental conditions is open and also affected by indeterminate sunlight,
the risks received the welders in watery eye and headache because of the welder are disobey in
using PPE while welding process.